[X1] 7. ET

1. Robot Assembly
1) Assembling the Robot
2) Verifying Cable Connections
2. Code Upload & Robot Operation
1) If You Are Not Coding
2) If You Are Coding the Program Yourself
① Preparing for Upload
② Coding the Program
③ Uploading the Code
④ Operating the Robot
3. Coding Examples
1) Moving the Robot Forwards and Backwards
Move Forward
Let’s make ET move forward at a speed of 20 for 1 second.
Since the DC motors with wheels are connected to the M1 and M2 ports, set the speed of both ‘M1’ and ‘M2′ to ’20’.
Move Backward
Let’s make ET move backward at a speed of 20 for 1 second.
If the speed value is prefixed with a ‘-‘, the DC motor will rotate in the opposite direction.
2) Rotating the Robot in Place
Rotate Left
Let’s make ET rotate in place to the left (counterclockwise) at a speed of 10 for 1 second.
Rotate Right
Let’s make ET rotate in place to the right (clockwise) at a speed of 10 for 1 second.
3) Making the Robot Dance
Move in the Following Sequence
Move in the Following Sequence
4. Troubleshooting Robot Issues
1) When the Power Does Not Turn On
  • Ensure the batteries are inserted with the correct polarity, matching the ‘+’ and ‘-‘ signs.
  • Verify that the jumper cap is properly inserted into the 12V power connector on the CPU board.
  • If there is no jumper cap available, use a 3×8 bolt to connect to the 12V power connector as an alternative.
  • Inspect the battery pack cable for any breaks or disconnections.
  • Ensure that the battery pack cable is securely connected to the 6V power connector on the CPU board.
2) When the DC Motor Does Not Rotate / Rotates in the Wrong Direction
  • Ensure that the motor cables are correctly connected to the motor port.
  • Check the motor cables for any signs of disconnection or damage.
  • Confirm that the motor cables are inserted vertically into the motor ports on the CPU board. If connected horizontally, the motor may not rotate.
  • Ensure the black wire of the motor cable is aligned with the arrow on the CPU board case. If connected in reverse, the DC motor will rotate in the opposite direction.
  • If the DC motor driver board is not inserted according to the assembly diagram, do not turn on the power. Insert it correctly as per the assembly diagram to avoid overheating risks during operation.
  • If the DC motor driver board is not inserted, place it properly and then turn on the power to check the operation.
3) When the Robot Operates Abnormally
  • Check that the cables are not caught in the drivetrain. If the cables are entangled with the drivetrain, the robot may not function properly.
  • Verify that the black wire of the 3-PIN cable is connected to the side with the white line on the X-keypad pin. (Inserting the 3-PIN cable in reverse can cause a short circuit, resetting the CPU board.)
  • Ensure that the black wire of the 3-PIN cable is aligned with the arrow on the CPU board case. (Reversing the 3-PIN cable can cause a short circuit, resetting the CPU board.)
  • If you want to repeat the last coded action, press the START button on the CPU board instead of the X-Keypad button to execute the code.
Scroll to Top